Preventive Maintenance Checklist

Heating Checklist

All service technicians will use the below listed checks when performing a clean and check on a furnace. Also, a diagnostic visit should not only fix the apparent problem but incorporate these checks as well. To separate ourselves from the ordinary, we must give our customers extraordinary service.

  • Check thermostat operation
  • Check pilot ignition sequence (adjust pilot)
  • Observe main burner operation
  • Check flue draft on natural draft furnaces
  • Test fan switch/heating fan relay operation
  • Check primary limit operation
  • Cycle furnace off, and record “fan off” temperature
  • Visually inspect heat exchanger
  • Check blower wheel for cleanliness
  • Check blower motor to include bearings, belts, pulleys
  • Check air filter (air cleaner)
  • Check furnace temperature rise
  • Fire furnace & leak check gas line from manual safety shutoff to main burners
  • Test flue spill switch operation
  • Check auxiliary limit switch operation
  • Test draft safeguard switch operation
  • Check humidifier operation
  • Operate furnace through one cycle
  • Clean furnace cabinet
  • Review results with customer (IAQ-Plumbing-Electrical)
  • Review service agreement with customer

Cooling Checklist

All service technicians will use the below listed checks when performing a clean and check on a A/C. Also, a diagnostic visit should not only fix the apparent problem but incorporate these checks as well. To separate ourselves from the ordinary, we must give our customers extraordinary service.

  • Check thermostat operation
  • Inspect filter at furnace
  • Inspect blower assembly
  • Inspect and lubricate blower motor
  • Take amperage reading of blower motor
  • Inspect condensate drain and flush if necessary
  • Inspect condenser coil
  • Inspect all electrical connections in condensing unit
  • Check service valves and service port caps
  • Check compressor voltage
  • Check contactor contacts for voltage drop
  • Read and record compressor discharge gas temperature
  • Read and record suction line temperature
  • Read and record liquid line temperature
  • Check evaporator coil performance
  • Check temperature drop across evaporator
  • Check unit operation according to charging calculator
  • Clean furnace cabinet
  • Cycle system through on e complete cycle
  • Reset thermostat
  • Review results with customer
  • Review IAQ issues with customer
  • Review plumbing issues with customer
  • Review electrical issues with customer
  • Review service agreement